Product Parameters

Rated Voltage 24VDC
Operating Voltage 18~32VDC
Protection Class IP68
Operating Ambient Temperature -50~+100°C
Applicable Medium Antifreeze
Applicable Medium Temperature -50~+100°C
Rated Current ≤11A
Load Noise ≤60dB(A)
Weight 2.2kg±5%(with Mounting Bracket)
Water Pump Rated Performance Parameters Q=3000L/h, H=13m, 240W
Operating Life ≥20000h


Specification

SLTBLDC-WP2418SY 规格图


SLTBLDC-WP2418SY pwm图SLTBLDC-WP2418SY 流量扬程性能 曲线图


Advantages

  • Extreme Environment Adaptability
    IP68 top-level protection defends against dust and water immersion, paired with an ultra-wide temperature range (-50°C to +100°C) for stable operation in harsh climates—ideal for all vehicle working conditions.
  • Flexible & Reliable Power Compatibility
    Broad operating voltage (18–32VDC) matches 24VDC rated systems perfectly, resisting voltage fluctuations and ensuring steady performance even in complex automotive electrical environments.
  • High Efficiency & Low Noise Operation
    Delivers powerful flow (3000L/h) and head (13m) with only 240W rated power; load noise ≤60dB(A) achieves quiet running, meeting vehicle interior noise standards.
  • Long-Durability & Low Maintenance Cost
    ≥20000h long operating life reduces replacement frequency; lightweight design (2.2kg±5% with bracket) cuts installation labor and space costs.


Application

Ideal for new energy vehicle thermal management systems, Sunlight water pumps serve as a reliable core component for coolant circulation in both passenger and commercial EVs. Engineered to thrive in extreme climate zones—from frigid high-altitude areas to scorching desert regions—they deliver consistent performance in dust-laden, high-humidity, and vibration-intensive working conditions.
Beyond automotive applications, these pumps are also widely adopted in industrial cooling systems and heavy-duty equipment where stable, low-maintenance fluid circulation is critical. Their compact, easy-to-install design seamlessly integrates into OEM assembly lines and aftermarket upgrade projects, catering to the needs of global vehicle manufacturers, thermal system integrators, and maintenance service providers.


SLTBLDC-WP2418SY 应用1SLTBLDC-2418SY应用4

SLTBLDC-WP2418SY应用3SLTBLDC-WP2418SY 应用2




Installation Tips

1.Secure the pump firmly with the matched mounting bracket to avoid vibration-induced wear during long-term operation; compatible with both OEM assembly lines and aftermarket retrofitting projects.

2.Ensure tight sealing of fluid connections to prevent leaks; the pump’s robust structure allows flexible installation in confined engine bays or industrial equipment compartments.

3.Match the pump with compatible vehicle/equipment electrical systems for stable power supply; no additional voltage regulators required for mainstream setups.

4.Install the pump in a well-ventilated location to optimize heat dissipation and further extend service life.


Usage Tips

1.Use dedicated coolant media recommended for automotive thermal management systems to avoid clogging or corrosion of internal components.

2.Perform regular visual inspections of connections and surfaces; keep the pump free from dust and debris accumulation to maintain peak performance.

3.The pump operates reliably in extreme temperature zones—no extra protective measures needed for frigid high-altitude areas or scorching desert environments.

4.Shut down the pump promptly if abnormal noise or performance issues occur; contact our after-sales team for professional troubleshooting guidance.


About Sunlight

Since 1990, Sunlight has specialized in manufacturing high-performance brushless fans and blowers. Certified with ISO9001 and IATF16949, our products meet CE, RoHS, and EMC standards. Widely applied in automotive, machinery, refrigeration and energy industries. Sunlight is committed to delivering quality, innovation, and reliable cooling solutions.

All fans undergo 100% testing before shipment, with customization and technical support available.


Ordering Information

Sample Lead Time: 14days

Mass Production: 21days

MOQ: 2

Customization: Voltage, control mode, wiring, housing treatment available

Contact Us:

Sunny Li: +86-18806140118 / sunny@sunlightmotor.com

Alisa Chen: +86-18806140198 / sales3@czsunlight.com

Frances Zhang: +86-18806140168/ sales1@czsunlight.com

Vicky Li: +86-18806140098/ sunlight@sunlightmotor.com 


FAQ

1.Q: What scenarios is this water pump suitable for?
A: It is a core component for new energy vehicle thermal management systems, and also widely applies to industrial cooling systems and heavy-duty equipment that require stable fluid circulation.
2.Q: Can the pump work normally in harsh environments?
A: Yes. It resists dust, water immersion and extreme temperature changes, performing stably in frigid high-altitude areas, scorching deserts and high-vibration working conditions.
3.Q: Is the pump easy to install and compatible with different systems?
A: Absolutely. Equipped with a dedicated mounting bracket, it fits seamlessly into OEM assembly lines and aftermarket retrofitting projects, and is compatible with mainstream electrical systems without extra regulators.
4.Q: How to maintain the pump to extend its service life?
A: Use professional coolant media, keep the pump surface free of dust and debris, and conduct regular visual inspections of connections—no complicated maintenance procedures are required.
5.Q: Will the pump generate excessive noise during operation?
A: No. It features low-noise operation, meeting the strict noise standards of vehicle interiors and industrial workshops, without affecting the surrounding working environment.


Previous: 
Next: