Brush DC Fan 12V 12inch in Puller 2540m³/H air volume SLT1212X-W5

12V 12-inch Brush DC Puller Fan – SLT1212X-W5 (≈ 2540 m³/h)

The SLT1212X-W5 is a 12V brushed DC axial fan in a puller configuration, designed to draw air through heat exchangers such as condensers or radiators. With a 305 mm (12″) diameter and rated airflow of approximately 2540 m³/h, it balances strong cooling capability and durable performance in demanding environments.

  • SLT1212X-W5

  • Sunlight

Voltage:
Availability:
Quantity:

Features of Brushed DC Fan  12V 12inch in Puller SLT1212X-W5


Max Fan Speed 2800rpm
Min Fan Speed 1000rpm
Weight 2.4KG
Operating supply voltage rang  12V
Operating working temperature range -40°C - 85°C
Storage temperature range -40°C - 100°C
Life time up to 8000 hours depending on missing profile



The drawing of dimension (mm) of Brushed DC Fan 12V 12inch in Puller SLT1212X-W5 

SLT1212X-003

Performance of Brushed DC Fan 12V 12inch in Puller SLT1212X-W5

SLT1212X-003


Airflow of Brushed DC Fan 12V 12inch in Puller SLT1212X-W5

The blue line is Airflow


SLT1212X-003



Advantages

  • Powerful Cooling Capacity – Provides up to 2540 m³/h of airflow to ensure fast and efficient heat dissipation even under high-load operation.

  • Compact and Sturdy Design – Engineered with a reinforced frame and balanced impeller for reduced vibration and longer durability.

  • Reliable in Extreme Conditions – Works smoothly from –40 °C to +85 °C, suitable for outdoor and heavy-duty environments.

  • Low Maintenance Operation – The brush DC motor offers stable performance with minimal service requirements.

  • Flexible Installation – Designed for puller configuration but adaptable to various radiator and condenser setups.

  • Customizable Options – Cable length, connector type, and mounting accessories can be tailored to your project needs.


Application

The SLT1212X-W5 is suitable for:

  • Vehicle Condenser / Radiator Systems – particularly when a puller fan is useful

  • Refrigeration / HVAC Units – to ensure airflow through dense fins

  • Construction / Heavy Machinery Cooling Systems

  • New Energy Vehicles / Electric Buses – integration in cooling modules

  • Industrial Enclosure / Electronics Cooling – where airflow needs to be drawn through components

Use Case Example: In a refrigeration truck condenser setup, the puller fan configuration improved coolant temperatures under high ambient load, stabilizing system performance.

brushless axial fan application - Sunlight Motor



About Sunlight

Since 1990, Sunlight has specialized in manufacturing high-performance brushless fans and blowers. Certified with ISO9001 and IATF16949, our products meet CE, RoHS, and EMC standards. Widely applied in automotive, machinery, refrigeration and energy industries. Sunlight is committed to delivering quality, innovation, and reliable cooling solutions.

All fans undergo 100% testing before shipment, with customization and technical support available.




Certifications


TS16949 certificate-for brushless fan - sunlight motorIATF I16949:2016 Certificate

IATF16949 for brushless fan - sunlight motorIATF 16949:2016 Certificate



EMC certificate for brushless fan - sunlight motorEMC Certificate

CE certificate for brushless fan - sunlight motorCE certificate



The Experimental Project 

无刷风机EMC认证_00


无刷风机EMC认证_01


无刷风机EMC认证_10


无刷风机EMC认证_03


无刷风机EMC认证_12


无刷风机EMC认证_27


无刷风机EMC认证_31


无刷风机EMC认证_32


无刷风机EMC认证_33


无刷风机EMC认证_34



Ordering Information

Sample Lead Time: 14days

Mass Production: 21days

MOQ: 2

Customization: Voltage, control mode, wiring, housing treatment available

Contact Us:

Sunny Li: +86-18806140118 / sunny@sunlightmotor.com

Alisa Chen: +86-18806140198 / sales3@czsunlight.com

Frances Zhang: +86-18806140168/ sales1@czsunlight.com

Vicky Li: +86-18806140098/ sunlight@sunlightmotor.com 



FAQ

Q1: What is the difference between a puller and a pusher fan?
A1: A puller fan draws air through the radiator or condenser, while a pusher fan blows air through it. The SLT1212X-W5 is a puller type, ideal for installations behind heat exchangers.

Q2: Can this fan run continuously for long periods?
A2: Yes. It is designed for continuous-duty operation and has been tested for long lifetime performance under harsh conditions.

Q3: Is the fan compatible with PWM speed controllers?
A3: While primarily voltage-controlled, it can also work with compatible external PWM or manual controllers for variable speed adjustment.

Q4: What kind of bearings does this fan use?
A4: It uses high-quality ball bearings that provide excellent durability, smooth rotation, and longer service life.

Q5: Can I use this fan in marine or outdoor environments?
A5: Yes, it can operate in outdoor or semi-exposed environments. For marine or high-humidity applications, an enhanced waterproof version can be provided upon request.